Reflectivity of antenna and mirrors reflectors at 110 and 200 GHz
DOI:
https://doi.org/10.1109/ICATT.2003.1238819Keywords:
metals reflectvity, millimeter wavesAbstract
Reflectivity (reflection loss) investigations of nickel samples with different types of surface finish, with and without rhodium coating, have been carried out in the 110-200 GHz frequency range on an installation developed in the Applied Physics Institute of Russia. The reflectivity measurements of high quality silver coated and gold coated mirrors are also presented. The reflectivity (reflection loss) investigations of some carbon fibre samples with and without aluminium coating have been made. Results are interesting, in view of the anisotropy of the carbon fibre material.References
Parshin, V.V.; The high quality mirrors for microwave range. Dig. of 23rd Int. Conf. on IR&MM Waves, UK, 1998, pp. 413-414.
Kasparek, W.; Fernandez, A.; Hollmann, F.; Wacker, R. Measurement of ohmic losses of metallic reflectors at 140 GHz using a 3-mirror resonator technique. Int J. of IR&MM Waves. No. 1, p. 1965-1707, 2001.
Parshin, V.V.; Myasnikova, S.E.; Valsecchi, G.; van ‘t Klooster, Kees. Reflectivity Investigations of Metal Samples in the Frequency Range 110-200 GHz. 25th Antenna Workshop on Satellite Antenna Technology, ESTEC, The Netherlands, pp. 689-696, 2002.
Krupnov, A.F.; Parshin, V.V.; Tretyakov, M.Y.; Shanin, V.N.; Myasnikova, S.E. Modern millimetre-wave spectroscopy of broad lines. Journal of Molecular Spectroscopy, Vol. 202, p. 107-115, 2000.